Thermal Wheel - Visually inspect for contamination, foreign objects, corrosion, and damage. Heating Coil - Visually inspect for contamination, foreign objects, corrosion, leakage, and damage. If anything noted, then clean or inspect/conduct remedial action.Ĭooling Coil - Visually inspect for contamination, foreign objects, corrosion, leakage, and damage.Įvaporator - Visually inspect for contamination, foreign objects, corrosion, leakage, and damage.Įvaporator - Visually inspect for any ice build-up.Ĭondenser - Visually inspect for contamination, foreign objects, corrosion, leakage, and damage.Ĭompressor - Inspect the oil levels to ensure they are in line with the manufacturers requirements.Ĭondensate Drain - Visually inspect pan for contamination, foreign objects, corrosion, and damage.Ĭondensate Drain Pan - Conduct flow test on drain pan, trap and pipework system. Heating Water - Take samples and analyse the water quality serving all wet coils to ensure it is in line with the original design requirements.įrost Coil - Visually inspect for contamination, foreign objects, corrosion, leakage, and damage. If anything noted, then conduct remedial action/lubricate.Ĭhilled Water - Take samples and analyse the water quality serving all wet coils to ensure it is in line with the original design requirements. If anything noted, then conduct remedial action.įan Motor - Inspect belts and pulley tensions, in line with the manufacturers requirements, and for wear and tear.Īny noted issues should be investigated, and remedial action taken.įan Motor - Inspect motor bearings for vibrations, noise, overheating and lubrication. Unit - Visually inspect the internal and external cleanliness of the unit. Steam Humidifier Control Panel - Visually inspect electrical connections, components, and cables for damage/issues. Steam Humidifier - Visually inspect drainage pipework for any blockages and obstructions. Steam Humidifier - Visually inspect the overall steam installation and supply pipework for any damage or leakage. Steam Humidifier - Visually inspect water levels. Steam Humidifier - Check for damage and leakage Steam Generator - Inspect for damage and leakage. Note: changes could impact the buildings energy usage. If it is not, investigate as to why and reset if no reason provided. Set Point - Visually Inspect temperature setting to ensure as per design/operational needs. If any are noted, they should be investigated further. Unit - Observe and review the unit for any changes in operating conditions.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |